TWR Obstruction Lighting HILS Controller 110V :
Connections : All control connections are galvanically isolated.
Lighting Protection : circuits as IEC
Standards : Complies with generic EMI (EN 50082-2 part 2) and EMC (EN 50081-2 part 2) RF immunity and emission standards
Power Consumption : 5W Continuous average
Power Requirements : 110V AC 50-60 Hz
Cable Entries : (3/4" NPT) Six entries. EMC glands provided as necessary
External Connection : Pinch screw wire connection terminals
Supervisor Functions : Flash character synchronization, up to 99 lights per single control unit. Control of light intensity according to ambient light conditions.
Information Functions : LCD backlit display screen. Membrane foil keyboard ''FAIL'' events log with historical data display. ''CONFIGURE'' screen allows adjustment of : photocell mode (i.e. auto / day / twilight / night). Real-time clock. LCD screen back light intensity.
Local : LCD display screen to show all ''FAIL'' events. LED-red on ''FAIL'' event. Reset/acknowledge ''FAIL'' conditions
Remote : Alarms 0-240VAC/DC, 2A max non inductive relay (dry) contacts for "FAIL'' of any system light (due to. missed flash, wrong color, wrong intensity) photocell status, marker light failure alarm, power failure, general system alarm warning
Enclosure : 19" Rack Mount